Items Inspected |
Details |
|
|
|
| Pins/Sockets | We verify that all pins are proper form and not pushed in. |
|
|
|
| Clean/Lube Slide Mechanism | Check for abnormal wear, tighten, clean and lubricate slide assembly. |
|
|
|
| Check Cylinders | Check cylinders for proper operation/air leaks, movement at slow speed. |
|
|
|
| Valves | Check valves for air leaks, or sticky valves. |
|
|
|
| Filter Bowl | Check and clean. |
|
|
|
| Air Lines | Check for possible wear, and leaks. |
|
|
|
| Internal wiring | Check for wear and shorts. |
|
|
|
| Pressure Switch/Dial | Check for proper operation. |
|
|
|
| Clean | Remove dust, debris from press, power supplies. |
|
|
|
| Pressure Gauges | Proper operation. |
|
|
|
| Transducer/Converter Contact | Proper contact exists, clean. |
|
|
|
| Bearing Assembly | Clean and lubricate. |
|
|
|
| Ultrasonic cables | Check for wear, breaks, pin condition and wear. |
|
|
|
| Operational Cables | Check pins, cable condition. |
|
|
|
| Stack Condition (Sonics) | Clean, oil free, and check surfaces and thread condition, lap components if necessary. |
|
|
|
| Meter Function | Make sure its functioning |
|
|
|
| Power Switch/Light Operation | Proper operation. Can be intermittent if they are older machines. |
|
|
|
| Power Cord | Wear, broken connections. |
|
|
|
| Timer Functions | Working properly. |
|
|
|
| Safety Devices | Make sure safety devices are installed and working properly. |